WEKO3
アイテム
帯広市八千代地域におけるヒートパイプを利用した大型実用低温貯蔵庫の開発
https://obihiro.repo.nii.ac.jp/records/639
https://obihiro.repo.nii.ac.jp/records/639b75506fb-c275-4174-a51d-37e325ef73d4
名前 / ファイル | ライセンス | アクション |
---|---|---|
energy.pdf (365.4 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2011-04-05 | |||||||||
タイトル | ||||||||||
タイトル | 帯広市八千代地域におけるヒートパイプを利用した大型実用低温貯蔵庫の開発 | |||||||||
言語 | ja | |||||||||
言語 | ||||||||||
言語 | jpn | |||||||||
キーワード | ||||||||||
言語 | ja | |||||||||
主題Scheme | Other | |||||||||
主題 | 雪氷 | |||||||||
キーワード | ||||||||||
言語 | ja | |||||||||
主題Scheme | Other | |||||||||
主題 | 冷熱エネルギー | |||||||||
キーワード | ||||||||||
言語 | ja | |||||||||
主題Scheme | Other | |||||||||
主題 | 凍土 | |||||||||
キーワード | ||||||||||
言語 | ja | |||||||||
主題Scheme | Other | |||||||||
主題 | 低温貯蔵 | |||||||||
キーワード | ||||||||||
言語 | ja | |||||||||
主題Scheme | Other | |||||||||
主題 | ヒートパイプ | |||||||||
キーワード | ||||||||||
言語 | en | |||||||||
主題Scheme | Other | |||||||||
主題 | Snow and Ice | |||||||||
キーワード | ||||||||||
言語 | en | |||||||||
主題Scheme | Other | |||||||||
主題 | Cold Energy | |||||||||
キーワード | ||||||||||
言語 | en | |||||||||
主題Scheme | Other | |||||||||
主題 | Ground Freezing | |||||||||
キーワード | ||||||||||
言語 | en | |||||||||
主題Scheme | Other | |||||||||
主題 | Low Temperature Storage | |||||||||
キーワード | ||||||||||
言語 | en | |||||||||
主題Scheme | Other | |||||||||
主題 | Heat pipes | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | journal article | |||||||||
その他(別言語等)のタイトル | ||||||||||
その他のタイトル | Development of Large Storage Facility for Practical Use under Low Temperature using Heat Pipes in Yachiyo Region in Obihiro, Hokkaido | |||||||||
言語 | en | |||||||||
著者 |
土谷, 富士夫
× 土谷, 富士夫
WEKO
285
|
|||||||||
抄録 | ||||||||||
内容記述タイプ | Abstract | |||||||||
内容記述 | The new large storage facility for the potato reservation was constructed in Yachiyo Region, the agricultural area of the suburbs from Obihiro City in November,2006. The 81 heat pipes were used for the cooling effect in this type storage system. The winter coldness was making the frozen ground on the storage wall by the thermal conduction of working heat pipes. So the cost of the maintenance was spent a little because of the natural energy, such as ice and snow. The floor size of the storage room was 109 in square meters and 60t of potatoes (May Queen) were stored from August to next June commercially. The frozen ground around the heat pipes was created to be 50cm thick during one winter and room temperature was kept under 5℃ until May. The quality of the preserved potatoes was investigated about the loss of the weight and the sugar contents. As the results,the loss of weight became 1.5% until the next August and the sugar content increased more than 10% during winter. | |||||||||
言語 | en | |||||||||
書誌情報 |
ja : 北海道自然エネルギー研究 en : Journal of Natural Energy Research Hokkaido 巻 6, p. 15-22, 発行日 2009 |
|||||||||
出版者 | ||||||||||
出版者 | 北海道自然エネルギー研究会 | |||||||||
言語 | ja | |||||||||
権利 | ||||||||||
言語 | ja | |||||||||
権利情報 | 北海道自然エネルギー研究会 | |||||||||
フォーマット | ||||||||||
内容記述タイプ | Other | |||||||||
内容記述 | application/pdf | |||||||||
著者版フラグ | ||||||||||
出版タイプ | VoR | |||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |