{"created":"2023-05-15T15:14:50.317260+00:00","id":275,"links":{},"metadata":{"_buckets":{"deposit":"64250886-466d-4dc7-8825-ee5eed66b81d"},"_deposit":{"created_by":12,"id":"275","owners":[12],"pid":{"revision_id":0,"type":"depid","value":"275"},"status":"published"},"_oai":{"id":"oai:obihiro.repo.nii.ac.jp:00000275","sets":["5"]},"author_link":["219","736","737","296"],"control_number":"275","item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"92","bibliographicPageStart":"85","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"Journal of Equine Science","bibliographic_titleLang":"en"}]}]},"item_2_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It is thought that in order to effectively treat gastrointestinal dysfunction, it should be detected at an early stage. The present study aimed to observe the movement via Electrointestinography (EIG) in the small intestine, cecum, right ventral colon and right dorsal colon, and to examine the procedure for assessing gastrointestinal function. Seven healthy thoroughbred horses were used. They were allowed food twice a day. EIG was measured at ten-minute intervals over a 24 hr period, and running spectral analysis was used. As a result, it was clear that EIG could non-invasively assess gastrointestinal function by setting the cut-off value of the frequency band to 1.8-12.0 cpm for a part of the digestive tract which is in a comparatively fixed position. The running spectral analysis could be used to visually interpret the change in the EIG power. In the small intestine, cecum, right ventral colon and right dorsal colon, a significant increase was observed for about 1-4 hr during which feeding took place at the maximum amplitude and the total power of the EIG wave. Because 3 cpm of the total power could be influenced by artifacts, analysis at 6 cpm is recommended, when the total power was assumed to be an indicator. In conclusion, it was considered capable of effectively detecting two indicators of 6 cpm of the total power and maximum amplitude for assessing change in the digestive tract voltage in medical practice.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Japanese Society of Equine Science"}]},"item_2_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.1294/jes.15.85","subitem_relation_type_select":"DOI"}}]},"item_2_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Japanese Society of Equine Science","subitem_rights_language":"en"}]},"item_2_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11010806","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13403516","subitem_source_identifier_type":"PISSN"}]},"item_2_subject_21":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"645","subitem_subject_scheme":"NDC"}]},"item_2_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{}],"affiliationNames":[{}]}],"creatorNames":[{"creatorName":"Sasaki, Naoki","creatorNameLang":"en"},{"creatorName":"佐々木, 直樹","creatorNameLang":"ja"}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Lee, Inhyung","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ayukawa, Yu","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamada, Haruo","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2018-01-30"}],"displaytype":"detail","filename":"Clinical.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Clinical.pdf","url":"https://obihiro.repo.nii.ac.jp/record/275/files/Clinical.pdf"},"version_id":"2a3fb061-1d27-4af2-9c05-6687a6d7e86c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"electrointestinography","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"equine","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"intestine","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"power spectral analysis","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"running spectral analysis","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Clinical Applications of Electrointestinography in the Horse","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Clinical Applications of Electrointestinography in the Horse","subitem_title_language":"en"}]},"item_type_id":"2","owner":"12","path":["5"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2011-10-27"},"publish_date":"2011-10-27","publish_status":"0","recid":"275","relation_version_is_last":true,"title":["Clinical Applications of Electrointestinography in the Horse"],"weko_creator_id":"12","weko_shared_id":-1},"updated":"2024-02-28T03:13:24.708282+00:00"}