WEKO3
アイテム
{"_buckets": {"deposit": "0f7e8c1f-7cb2-4d13-ba55-52247a963d5a"}, "_deposit": {"created_by": 12, "id": "4460", "owners": [12], "pid": {"revision_id": 0, "type": "depid", "value": "4460"}, "status": "published"}, "_oai": {"id": "oai:obihiro.repo.nii.ac.jp:00004460", "sets": ["5"]}, "author_link": ["6355", "6356", "6357", "110", "6358"], "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "conference 1", "bibliographicPageStart": "012088", "bibliographicVolumeNumber": "294", "bibliographic_titles": [{"bibliographic_title": "IOP Conference Series: Earth and Environmental Science", "bibliographic_titleLang": "en"}]}]}, "item_2_description_19": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This paper presents the results of a preliminary experiment using test cells constructed in Bandung, Indonesia. We particularly analysed the thermal effects by comparing green walls with wooden blinds in contrast with those of no covering materials to determine the factors affecting the improvements of indoor thermal conditions in hot-humid climates. The results showed that, unexpectedly, indoor thermal conditions were not improved when green walls/blinds were installed, at least at the center of the units. Nevertheless, air temperatures behind the green walls were found to be lower than those of the other conditions. Moreover, the factors affecting the Standard Effective Temperature (SET*) were analysed in detail by dividing SET* into four thermal factors in terms of temperature, including air temperature, radiation, humidity and wind speed. The further analysis showed that the increases in SET* in the units with green walls were mainly attributed to the reduction of wind velocities (36–45%). It can be concluded that the airflow blockage effect by the green walls was larger than its transpiration cooling effect at the center of the units.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": " IOP Publishing", "subitem_publisher_language": "en"}]}, "item_2_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "info:doi/10.1088/1755-1315/294/1/012088", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "This is an open access article licensed under the terms of the Creative Commons Attribution (by) License. \u003chttp://creativecommons.org/lisenses/by/4.0/\u003e", "subitem_rights_language": "en"}]}, "item_2_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "17551307", "subitem_source_identifier_type": "PISSN"}]}, "item_2_subject_21": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "470", "subitem_subject_scheme": "NDC"}]}, "item_2_text_25": {"attribute_name": "文献提供者", "attribute_value_mlt": [{"subitem_text_value": "小山耕平(koyama@obihiro.ac.jp)"}]}, "item_2_textarea_24": {"attribute_name": "作業記録", "attribute_value_mlt": [{"subitem_textarea_value": "2019/10/27小山先生から提供有り。著作権OK。2019/10/28登録"}]}, "item_2_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kitagawa, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6355", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanimoto, A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6356", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kubota, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6357", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koyama, Kohei", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "110", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "9000018568549", "nameIdentifierScheme": "CiNii ID", "nameIdentifierURI": "http://ci.nii.ac.jp/nrid/9000018568549"}, {"nameIdentifier": "70709170", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70709170"}, {"nameIdentifier": "0000-0001-6707-3130", "nameIdentifierScheme": "ORCID", "nameIdentifierURI": "https://orcid.org/0000-0001-6707-3130"}]}, {"creatorNames": [{"creatorName": "Alfata, MNF", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6358", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-10-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Kitagawa_2019_IOP_Conf._Ser.__Earth_Environ._Sci._294_012088.pdf", "filesize": [{"value": "2.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_6", "mimetype": "application/pdf", "size": 2100000.0, "url": {"label": "fulltext", "url": "https://obihiro.repo.nii.ac.jp/record/4460/files/Kitagawa_2019_IOP_Conf._Ser.__Earth_Environ._Sci._294_012088.pdf"}, "version_id": "dd1af252-b1a7-45aa-a2e2-52fba5719aac"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A field experiment on green walls taking into consideration wind flow in the hot-humid climate of Indonesia", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A field experiment on green walls taking into consideration wind flow in the hot-humid climate of Indonesia", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "12", "path": ["5"], "permalink_uri": "https://obihiro.repo.nii.ac.jp/records/4460", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2019-10-28"}, "publish_date": "2019-10-28", "publish_status": "0", "recid": "4460", "relation": {}, "relation_version_is_last": true, "title": ["A field experiment on green walls taking into consideration wind flow in the hot-humid climate of Indonesia"], "weko_shared_id": -1}
A field experiment on green walls taking into consideration wind flow in the hot-humid climate of Indonesia
https://obihiro.repo.nii.ac.jp/records/4460
https://obihiro.repo.nii.ac.jp/records/44607f11def2-ac5c-4720-835a-211f864a570b
名前 / ファイル | ライセンス | アクション |
---|---|---|
fulltext (2.1 MB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2019-10-28 | |||||||
タイトル | ||||||||
言語 | en | |||||||
タイトル | A field experiment on green walls taking into consideration wind flow in the hot-humid climate of Indonesia | |||||||
言語 | ||||||||
言語 | eng | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
著者 |
Kitagawa, H.
× Kitagawa, H.× Tanimoto, A.× Kubota, T.× Koyama, Kohei
WEKO
110
× Alfata, MNF |
|||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | This paper presents the results of a preliminary experiment using test cells constructed in Bandung, Indonesia. We particularly analysed the thermal effects by comparing green walls with wooden blinds in contrast with those of no covering materials to determine the factors affecting the improvements of indoor thermal conditions in hot-humid climates. The results showed that, unexpectedly, indoor thermal conditions were not improved when green walls/blinds were installed, at least at the center of the units. Nevertheless, air temperatures behind the green walls were found to be lower than those of the other conditions. Moreover, the factors affecting the Standard Effective Temperature (SET*) were analysed in detail by dividing SET* into four thermal factors in terms of temperature, including air temperature, radiation, humidity and wind speed. The further analysis showed that the increases in SET* in the units with green walls were mainly attributed to the reduction of wind velocities (36–45%). It can be concluded that the airflow blockage effect by the green walls was larger than its transpiration cooling effect at the center of the units. | |||||||
言語 | en | |||||||
書誌情報 |
en : IOP Conference Series: Earth and Environmental Science 巻 294, 号 conference 1, p. 012088, 発行日 2019 |
|||||||
出版者 | ||||||||
言語 | en | |||||||
出版者 | IOP Publishing | |||||||
ISSN | ||||||||
収録物識別子タイプ | PISSN | |||||||
収録物識別子 | 17551307 | |||||||
DOI | ||||||||
関連タイプ | isIdenticalTo | |||||||
識別子タイプ | DOI | |||||||
関連識別子 | info:doi/10.1088/1755-1315/294/1/012088 | |||||||
権利 | ||||||||
言語 | en | |||||||
権利情報 | This is an open access article licensed under the terms of the Creative Commons Attribution (by) License. <http://creativecommons.org/lisenses/by/4.0/> | |||||||
フォーマット | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | application/pdf | |||||||
著者版フラグ | ||||||||
出版タイプ | VoR | |||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||
日本十進分類法 | ||||||||
主題Scheme | NDC | |||||||
主題 | 470 |